22 Results found

Reducer bushings

Reducer bushings adjust the pipe jacket diameter to fit the respective branch diameter on the Straight, Tee, Elbow or H-Insulation Kits.

Shrink sleeve for connection vault

Shrink sleeves ensure a watertight seal between the Ecoflex pipe and the exterior of the connection vault. Shrink sleeves may also repair minor damage to the corrugated HPDE jacket of Ecoflex pipe.Note: Refer to the Pre-insulated Pipe Systems Design and Installation Manual for installation and repair procedures.

Shrinkable repair tape

Uponor shrinkable tape repairs minor damage to the corrugated HPDE jacket of Ecoflex pipe.Note: Refer to the Pre-insulated Pipe Systems Design and Installation Manual for installation and repair procedures.

Single EPDM rubber end caps

EPDM rubber end caps seal the exposed insulation between the jacket and service pipe after the pipe is cut to make a connection. Each end cap includes a stainless-steel clamp and an EPDM rubber O-ring.Note: Uponor requires end caps at all ends of the piping system to ensure system integrity.Single EPDM rubber end caps are used with Ecoflex thermal single pipes, Ecoflex potable HDPE pipes and Ecoflex potable PEX single pipes.

Straight insulation kits

All pre-insulated pipe systems insulation kits make insulated connections of single or twin-style Ecoflex pre-insulated pipe with a jacket size of 5.5", 6.9" and 7.9". The kits feature two shells, stainless-steel bolts, plastic pins and joint-sealing compound. Note: Uponor ProPEX fittings and EPDM rubber end caps are required at all ends of the piping system to ensure system integrity. Straight insulation kit makes an insulated straight connection of single or twin-style Ecoflex pre-insulated pipe.

Tee insulation kits

All pre-insulated pipe systems insulation kits make insulated connections of single or twin-style Ecoflex pre-insulated pipe with a jacket size of 5.5", 6.9" and 7.9". The kits feature two shells, stainless-steel bolts, plastic pins and joint-sealing compound. Note: Uponor ProPEX fittings and EPDM rubber end caps are required at all ends of the piping system to ensure system integrity. Tee insulation kit makes an insulated tee connection of single or twin-style Ecoflex pre-insulated pipe.

Twin EPDM rubber end caps

EPDM rubber end caps seal the exposed insulation between the jacket and service pipe after the pipe is cut to make a connection. Each end cap includes a stainless-steel clamp and an EPDM rubber O-ring.Note: Uponor requires end caps at all ends of the piping system to ensure system integrity.Twin EPDM end caps are used with Ecoflex thermal twin pipes and Ecoflex potable PEX twin pipes.

Wall sleeves with heat shrink seal kits

Wall sleeves with heat shrink seal kits offer a simple installation for new-block construction or existing walls with irregular holes. The wall sleeve is not engineered for specific bearing loads, but offered for installation convenience and compatibility.

Connection vaults

Connection vaults provide a fully watertight, insulated enclosure for multiple straight-through and branch connections. Buried underground, connection vaults allow the system designer to virtually eliminate all branch connections typical in traditional underground system design. Step-down outlets are compatible with the majority of Ecoflex piping.