Uponor Fluvia T pumpgroup Push-12 AC-G

- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W
- Bracket for left or right installation
- Air bleed screw
- Secondary circuit temp. range 20-50°C
- Balancing valve
- Secondary loop 3/4" Eurocone
- Primary valves with clampconnection for CU-Pipe 15mm
- For control of UFH in small zones
- Max. primary temperature: 90°C
- Max. secondary temperature: 55°C
- Pumpgroup with actuator 230 V and cable room sensor
- Secondary max. temperature limiter 50°C

Uponor Fluvia T pumpgroup MPG-UK

- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W
- Bracket for left or right installation
- Air bleed screw
- Secondary circuit temp. range 20-50°C
- Balancing valve
- Secondary loop 3/4" Eurocone
- Primary valves with clamp connection for CU-Pipe 15mm
- For control of UFH in small zones
- Max. primary temperature: 90°C
- Max. secondary temperature: 55°C
- Maximal heat load: 15 kW
- kvs flow valve: 3,2 m3/h
- Water temperature and flow rates controlled by thermostatic 4 way valve

Uponor Fluvia pump Wilo Para SC

- Wilo pump 130mm for pump group MPG UK
- Wilo pump 180mm for pump groups CPG

Uponor Fluvia Y compression adapter

- Made of brass
- For extension of PUSH-12 pump groups with 2 loops

Uponor Fluvia Pump IMP NMT mini

- For pump groups: Push 23, MPG and KRS 6

Uponor Base controller H pump X-60

- Controller with autobalance function for 230V standard wiring
- Supports up to 6 thermostats (230V)
- Supports up to 12 actuators (230V), with 2 actuators at a time that follow a common thermostat (6x 2 actuators)
- Noiseless actuator switching
- Autobalancing in heating optimises energy use and comfort
- Switch to enable/disable the autobalance function
- Pump relay
- Time limit by-pass with autobalance
- Input: day/night switch
- 4 wires for thermostat connection
- Works with 3 wires thermostat (2 wires for power supply 230 V, 1 output 230 V demand) and 4 wires
- thermostat for full functionality (day/night signal)
- Connection terminals for thermostat/actuator 0,13 ... 1,5 mm²
- Overload protection
- Protection class: IP20

- Consisting of:
- Uponor Base controller X-60
- Without power cable
- Mounting material, DIN rail included

Uponor Base controller box 8X UK

- Supports up to 8 thermostats
- Supports up to 16 actuators
- Pump control
- Boiler control
- Night set back, 2 time zones
- Overload protection
- Optional: 2 time zone night setback if connected to timer (1002133 sold seperately)
- Effective power per TA 230: 3W
- Protection class: IP20

- Consisting of:
- Uponor Base controller box 8X
- Connection port for time clock
- Cable clambs
- Mounting material