Heating & Cooling Solutions

389 Results found

Uponor Ecoflex additional insert

- For concrete core hole or fibre cement pipe
- Part to eliminate radial stress of the casing pipe
- Used with Uponor wall seal PWP

Uponor Ecoflex fibre cement pipe PWP

- Enbed in a brick wall or concrete wall
- Alternative to water-proof concrete core hole
- Applicable for Uponor wall seal PWP (pressurized water)
- "Dimension" = used for jacket pipe diameter

Uponor Ecoflex wall sleeve set NPW

- For concrete-cast and brick walls
- Applicable for NWP = no pressurized water area
- Contain PE pipe and shrink sleeve

Uponor Ecoflex conduit angle

- Conduit used for Ecoflex pipe enter through the base plate the building

Uponor Ecoflex pipe bend support

- Guiding 90° the Ecoflex pipes in base floor penetration
- Metal support braces can be linked together

Uponor Ecoflex repair sleeve

- Shrink sleeve to seal damages in casing pipe

Uponor Ecoflex shrink tape

- Shrinkable tape use for sealing damaged casing pipes

Uponor Ecoflex trench warning tape, red

- For marking the position of buried Ecoflex pipes
- Tape marking with required application symbols

Uponor Combi Port M-Base HeatInterface RC

RC version for domestic hot water and direct heating with radiator connection (no mixing circuit). Mixing circuit can be upgraded by using the dedicated cabinet with installed UFH mixing group (Uponor Combi Port M-Base Cabinet+manif IW-UFH). Bypass function can be upgraded by using special accessory - Uponor Combi Port M-Base Heat Bypass.
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
ZV – zone valve in residential heating circuit return line without actuator
NI – no pipe insulation and/or insulated cover

Uponor Combi Port M-Pro HeatInterface UFH

UFH version for domestic hot water and direct heating with underfloor heating connection (including mixing circuit with heating pump).
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
St – free of non-ferrous metal brazed stainless steel heat exchanger for domestic hot water preparation
BP – supply lines preheating function
DT – differential pressure controller at the heat interface unit heat circuit for domestic hot water preparation
ZM - circulation module for domestic hot water with safety valve, circulation pump, and differential pressure regulator. A waste water connection is needed.
MS – mixing set with heating pump, thermostat, and non-return valve for apartment heating circuit
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
UL – thermostatic temperature limiter for underfloor heating circuit
SS – safety thermostatic switch for apartment heating circuit
ZA - zone valve in residential heating circuit return line with 2-point actuator included
2C – second direct heating circuit connections with extra zone valve (no actuator, no mixing circuit)

Uponor Combi Port M-Pro HeatInterface RC

RC version for domestic hot water and direct heating with radiator connection (no mixing circuit).
Dimensioning codes:
15,19 – domestic hot water capacity indication (l/min)
CB – copper brazed stainless steel heat exchanger for domestic hot water preparation
St – free of non-ferrous metal brazed stainless steel heat exchanger for domestic hot water preparation
BP – supply lines preheating function
DI – primary differential pressure controller at the heat interface unit inlet
DT – differential pressure controller at the heat interface unit heat circuit for domestic hot water preparation
TL – thermostatic temperature limiter for domestic hot water with submersible sensor
RL – return temperature limiter for apartment heating circuit
ZM – circulation module for domestic hot water with safety valve, circulation pump, and differential pressure regulator. A waste water connection is needed.
ZV – zone valve in residential heating circuit return line without actuator