Uponor MLC white insulated S13 BL-S2-D0

- Coil
- Pre-insulated, with foil vapour barrier
- Fire class Bl- s1, d0 to BS EN 13501-1 (Insulation assembly)

Uponor MLC white insulated S13 BL-S2-D0

Item details

Uponor MLC white insulated S13 BL-S2-D0 16x2 blue 75m
Uponor MLC white insulated S13 BL-S2-D0 16x2 red 75m
Uponor MLC white insulated S13 BL-S2-D0 20x2,25 blue 75m
Uponor MLC white insulated S13 BL-S2-D0 20x2,25 red 75m
Uponor MLC white insulated S13 BL-S2-D0 25x2,5 blue 50m

Documents

Technical information
12 KB1142162

TI MLC tap water heating UK 1142162

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Approval Certificate
282 B1030970

UPONOR CER RTM SYS MECH WRAS 2203909 GB EN (1030970)

Approval Certificate
150 B0000115559

Uponor CER S-Press PLUS FIT MECH KIWA_Regulation_4_2505703 GB_EN (0000115559)

Approval Certificate
262 B1095152

Uponor CER S-Press PLUS SYS MECH WRAS 1903901 GB (1095152)

About

Specification

Uponor MLC (Multi Layer Composite).

- PE-RT/AL/PE-RT - 5 layer composite pipe consisting of an
Aluminium pipe , bonded to an inner layer of Polyethylene
Raised Temperature (PE-RT), and an outer layer of white
Polyethylene Raised Temperature (PE-RT).
- 100% oxygen-proof diffusion barrier, exceeding the
requirements of DIN 4726
- Manufactured to BS EN ISO 21003-1 2008.
- Pipes are marked at 1m intervals with full production data,
in accordance with the requirements of the standard.
- Sizes 12 - 32mm supplied as flexible coils, or 40-110mm
as extra rigid straight lengths.

Application

Tested/approved according to BS EN ISO 21003 Multilayer
piping systems for hot and cold water installations inside
buildings for application class 1,2,4,5/10bar

Domestic water services: The permanent operating
temperature from 20°C to 70°C at a maximum permanent
operating pressure of 10 bar. The short-term malfunction
temperature is 95°C for a period of 100 hours in the operating
life time.

Domestic cold water services : where the water temperature
does not exceed 20°C at a maximum permanent operating
pressure of 16bar.

Heating: The permanent operating temperature ranges up
to 80°C at a maximum permanent operating pressure of 10 bar.
The short-term malfunction temperature is 100°C for a period
of 100 hours in the operating life time.

Certification

UK Reg4 approval
- WRAS or
- KIWA
to meet the requirements of the Water Supply (Water Fittings) Regulations 1999

Product drawings

1093952_LAB
1093952
29 B
1093953_LAB
1093953
29 B
1093954_LAB
1093954
29 B
1093955_LAB
1093955
29 B
1094883_LAB
1094883
32 B
1093952_REN
1093952
31 B
1093953_REN
1093953
34 B
1093954_REN
1093954
33 B
1093955_REN
1093955
34 B
1094883_REN
1094883
34 B
1093952_ZMD
1093952
166 B