Fill the BIM cart from the product catalogue

Uponor S-Press PLUS coupling PPSU

- Material: PPSU

Uponor S-Press PLUS coupling PPSU

Item details

Uponor S-Press PLUS coupling PPSU 16-16
Uponor S-Press PLUS coupling PPSU 20-20
Uponor S-Press PLUS coupling PPSU 25-25
Uponor S-Press PLUS coupling PPSU 32-32

Documents

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
150 B0000115559

Uponor CER S-Press PLUS FIT MECH KIWA_Regulation_4_2505703 GB_EN (0000115559)

Approval Certificate
262 B1095152

Uponor CER S-Press PLUS SYS MECH WRAS 1903901 GB (1095152)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

Environmental Product Declaration (EPD)
936 B1162873

Uponor EPD S-Press PLUS (1162873)

About

Specification

- Unique press indicator foil
- Fast 3-step installation (press without bevel)
- Innovative QR code for immediate digital access
- Colour coded
- Fixed press sleeve with inspection windows
- Precise jaw location
- Fast diameter recognition
- Accurate test safety function
- 100% backward compatible with existing Uponor components
- Flow rate optimized fitting body

Application

Tested/approved according to BS EN ISO 21003 Multilayer
piping systems for hot and cold water installations inside
buildings for application class 1,2,4,5/10bar

Domestic water services: The permanent operating
temperature from 20°C to 70°C at a maximum permanent
operating pressure of 10 bar. The short-term malfunction
temperature is 95°C for a period of 100 hours in the operating
life time.

Domestic cold water services : where the water temperature
does not exceed 20°C at a maximum permanent operating
pressure of 16bar.

Heating: The permanent operating temperature ranges up
to 80°C at a maximum permanent operating pressure of 10 bar.
The short-term malfunction temperature is 100°C for a period
of 100 hours in the operating life time.

Certification

UK Reg4 approval
- WRAS or
- KIWA
to meet the requirements of the Water Supply (Water Fittings) Regulations 1999

Product drawings

1039933_ZMD
1039933
240 B
1039934_ZMD
1039934
236 B
1039935_ZMD
1039935
236 B
1039936_ZMD
1039936
236 B
1039933_LAB
1039933
73 B
1039934_LAB
1039934
73 B
1039935_LAB
1039935
73 B
1039936_LAB
1039936
73 B
1039933_REN
1039933
111 B
1039934_REN
1039934
37 B
1039935_REN
1039935
38 B
1039936_REN
1039936
40 B