Fill the BIM cart from the product catalogue

Uponor Uni Pipe PLUS white insulated S10 WLS 035

- Coil
- Insulation thickness 10 mm
- Thermal conductivity λ=0,035 W/m*k
- Round extruded
- Fire Class E to BS EN 13501-1

Uponor Uni Pipe PLUS white insulated S10 WLS 035

Item details

Uponor Uni Pipe PLUS white insulated S10 WLS 035 14x2,0 blue 75m
Uponor Uni Pipe PLUS white insulated S10 WLS 035 16x2,0 blue 75m
Uponor Uni Pipe PLUS white insulated S10 WLS 035 20x2,25 blue 75m
Uponor Uni Pipe PLUS white insulated S10 WLS 035 25x2,5 blue 50m

Documents

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
277 B1119612

UPONOR CER MLC SYS MECH WRAS 2010907 GB EN (1119612)

Approval Certificate
282 B1030970

UPONOR CER RTM SYS MECH WRAS 2203909 GB EN (1030970)

Approval Certificate
150 B0000115559

Uponor CER S-Press PLUS FIT MECH KIWA_Regulation_4_2505703 GB_EN (0000115559)

About

Specification

Uponor Uni Pipe PLUS Seamless Aluminium Composite (SAC).

PE-RT/AL/PE-RT - 5 layer composite pipe consisting of an
Aluminium pipe (100% oxygen-proof diffusion barrier, exceeding
the requirements of DIN 4726), bonded to an inner layer of
Polyethylene Raised Temperature (PE-RT), and an outer layer
of white Polyethylene Raised Temperature (PE-RT).
- Manufactured to BS EN ISO 21003-1 2008.
- Pipes are marked at 1m intervals with full production data
in accordance with the requirements of the standard.
- Sizes 14-32 mm supplied as flexible coils
- Sizes 16-32 mm as extra rigid straight lengths.

Application

Tested/approved according to BS EN ISO 21003 Multilayer
piping systems for hot and cold water installations inside
buildings for application class 1,2,4,5/10bar

Domestic water services: The permanent operating
temperature from 20°C to 70°C at a maximum permanent
operating pressure of 10 bar. The short-term malfunction
temperature is 95°C for a period of 100 hours in the operating
life time.

Domestic cold water services : where the water temperature
does not exceed 20°C at a maximum permanent operating
pressure of 16bar.

Heating: The permanent operating temperature ranges up
to 80°C at a maximum permanent operating pressure of 10 bar.
The short-term malfunction temperature is 100°C for a period
of 100 hours in the operating life time.

Certification

UK Reg4 approval
- WRAS or
- KIWA
To meet the requirements of the
Water Supply (Water Fittings) Regulations 1999

Product drawings

1062181_LAB
1062181
42 B
1062182_LAB
1062182
42 B
1062183_LAB
1062183
42 B
1160885_LAB
1160885
42 B
1062181_ZMD
1062181
157 B
1062182_ZMD
1062182
157 B
1062183_ZMD
1062183
157 B
1160885_ZMD
1160885
161 B
1062181_REN
1062181
174 B
1062181_REN
1062181
61 B
1062182_REN
1062182
61 B
1062183_REN
1062183
61 B
1160885_REN
1160885
61 B