Uponor UK
Head Office
Uponor UK
The Pavillion
Blackmoor Lane
Watford Hertfordshiree
WD18 8GA

Uponor RS flange adapter

- Made of tin-plated brass
- Fits to all RS2 or RS3 base parts
- Flange PN6/PN16 acc. to EN 1092-3
- Bolt circle with 4/8 holes.

Uponor RS flange adapter

Item details

Uponor RS flange adapter RS2-DN65 (PN6)
Uponor RS flange adapter RS2-DN65 (PN16)
Uponor RS flange adapter RS3-DN80 (PN6)
Uponor RS flange adapter RS3-DN80 (PN16)
Uponor RS flange adapter RS3-DN100 (PN6)
Uponor RS flange adapter RS3-DN100 (PN16)

Documents

Installation Manual
2 KB1044657

Installation Manual RS (1044657)

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

Approval Certificate
409 B1013450

UPONOR SAMPLE MLC PIPE WHITE 50X4,5 LENGTH 30CM

Approval Certificate
409 B1013402

UPONOR SAMPLE MLC PIPE WHITE 32X3 LENGTH 30CM (1013402)

About

Specification

- with fixed press sleeve
- stop ring
- colour code
- Test safety

Application

-Heating systems (high temperature radiators) - where the water temperature does not continuously exceed 80ºC, 10 bar (Conditions to application Class 5 - BS EN ISO 21003-1:2008). The maximum short-term malfunction temperature is 100ºC for an accumulative 100 hours over the working life of the system. (Heating systems must be installed with room and water temperature controls in accordance with the current Building Regulations Parts L1 (Energy – Dwellings) and L2 (Energy – Non Dwellings) for England and Wales, or an equivalent national standard for Scotland or Republic of Ireland)
-Cold water domestic services: 0°C to 20°C where the water temperature does not exceed 20ºC, 16bar
-Hot water domestic services: 20°C to 70°C where the water temperature does not continuously exceed 70ºC, 10 bar (Conditions to application Class 2 - BS EN ISO 21003-1:2008). The maximum short-term malfunction temperature is 95ºC for an accumulative 100 hours over the working life of the system.
-Uponor multi-layer pipe can be used for DHW recirculating systems, provided the operating temperatures and pressures do not exceed the maximum conditions detailed under 'Domestic Services'
-Chilled water: -10°C to 10°C,10 bar. If risk of damage from freezing, a suitable anti-freeze additive must be used. Any additive must be suitable for use with Polyethylene, PPSU, EPDM and CW625N brass
if not different mentioned:
- Male and female threads acc.to EN 10226-1.

Certification

-WRAS : 1903901 - Uponor S-Press PLUS, S-Press PLUS, PPSU, MLC and SAC 16-32mm
-WRAS : 2010907 - Uponor S-Press 12 & 14mm, MLC
-WRAS : 2109108 - S-Press & RS Modular 40-110mm, MLC
-KIWA – UK water Regulation 4
-Manufacturing is in accordance with the international quality standard ISO 9001 and environmental standard ISO 14001.

Product drawings

1029129_ZMD
1029129
123 B
1029130_ZMD
1029130
123 B
1059398_ZMD
1059398
123 B
1059399_ZMD
1059399
123 B
1059400_ZMD
1059400
123 B
1059401_ZMD
1059401
123 B
1029129_REN
1029129
54 B
1029130_REN
1029130
54 B
1059398_REN
1059398
165 B
1059398_REN
1059398
54 B
1059399_REN
1059399
54 B
1059400_REN
1059400
54 B
1059401_REN
1059401
54 B
1029129_LAB
1029129
97 B
1029130_LAB
1029130
97 B
1059398_LAB
1059398
97 B
1059399_LAB
1059399
97 B
1059400_LAB
1059400
97 B
1059401_LAB
1059401
97 B