Uponor UK
Head Office
Uponor UK
The Pavillion
Blackmoor Lane
Watford Hertfordshiree
WD18 8GA

Uponor S-Press tee reducer PPSU

- Fast installation with easy bevel and without calibration
- Colour code

Uponor S-Press tee reducer PPSU

Item details

Uponor S-Press tee reducer PPSU 40-20-40
1039963

Uponor S-Press tee reducer PPSU 40-25-32

Item available on request, minimum lead time 2 weeks
Uponor S-Press tee reducer PPSU 40-25-32
Uponor S-Press tee reducer PPSU 40-25-40
Uponor S-Press tee reducer PPSU 40-32-32
Uponor S-Press tee reducer PPSU 40-32-40
Uponor S-Press tee reducer PPSU 50-25-40
Uponor S-Press tee reducer PPSU 50-25-50
Uponor S-Press tee reducer PPSU 50-32-50

Documents

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Installation Report
110 B1120118

Installation Report MLC leak test report TW air-gas (1120118)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

About

Specification

- with fixed press sleeve
- stop ring
- test safety

Application

-Heating systems (high temperature radiators) - where the water temperature does not continuously exceed 80ºC, 10 bar (Conditions to application Class 5 - BS EN ISO 21003-1:2008). The maximum short-term malfunction temperature is 100ºC for an accumulative 100 hours over the working life of the system. (Heating systems must be installed with room and water temperature controls in accordance with the current Building Regulations Parts L1 (Energy – Dwellings) and L2 (Energy – Non Dwellings) for England and Wales, or an equivalent national standard for Scotland or Republic of Ireland)
-Cold water domestic services: 0°C to 20°C where the water temperature does not exceed 20ºC, 16bar
-Hot water domestic services: 20°C to 70°C where the water temperature does not continuously exceed 70ºC, 10 bar (Conditions to application Class 2 - BS EN ISO 21003-1:2008). The maximum short-term malfunction temperature is 95ºC for an accumulative 100 hours over the working life of the system.
-Uponor multi-layer pipe can be used for DHW recirculating systems, provided the operating temperatures and pressures do not exceed the maximum conditions detailed under 'Domestic Services'
-Chilled water: -10°C to 10°C,10 bar. If risk of damage from freezing, a suitable anti-freeze additive must be used. Any additive must be suitable for use with Polyethylene, PPSU, EPDM and CW625N brass
if not different mentioned:
- Male and female threads acc.to EN 10226-1.

Certification

-WRAS : 2010907 - Uponor S-Press 12 & 14mm, MLC
-WRAS : 2109108 - S-Press & RS Modular 40-110mm, MLC
-KIWA – UK water Regulation 4
-Manufacturing is in accordance with the international quality standard ISO 9001 and environmental standard ISO 14001

Product drawings

1039962_ZMD
1039962
198 B
1039963_ZMD
1039963
198 B
1039964_ZMD
1039964
198 B
1039965_ZMD
1039965
198 B
1039966_ZMD
1039966
198 B
1039967_ZMD
1039967
198 B
1039968_ZMD
1039968
198 B
1039969_ZMD
1039969
198 B
1039962_LAB
1039962
85 B
1039963_LAB
1039963
85 B
1039964_LAB
1039964
85 B
1039965_LAB
1039965
85 B
1039966_LAB
1039966
85 B
1039967_LAB
1039967
85 B
1039968_LAB
1039968
85 B
1039969_LAB
1039969
85 B
1039962_REN
1039962
71 B
1039963_REN
1039963
85 B
1039964_REN
1039964
85 B
1039965_REN
1039965
88 B
1039966_REN
1039966
84 B
1039967_REN
1039967
88 B
1039968_REN
1039968
92 B
1039969_REN
1039969
102 B