Fill the BIM cart from the product catalogue

1122 Results found

GF Uponor Vario PLUS flowmeter

- With shut-off function

GF Uponor Vario PLUS supply valve inset scale 1-5, scale 1-5

- For flow regulation in supply bar in Vario Plus manifold
- With shut-off function

GF Uponor Vario PLUS return valve inset

- For flow regulation in return, shut-off function

GF Uponor Vario PLUS thermometer

- Made of polycarbonate
- For mounting at the connection set
- Consists of two click thermometers

GF Uponor Vario return valve inset COMP

- for Velta Compact Manifold since 1987

GF Uponor Vario manifold flowmeter

- For Vario S
- Flow range 0-5 l/min

GF Uponor Fluvia T pump group Push-12 TH-G

- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W
- Bracket for left or right installation
- Air bleed screw
- Secondary circuit temp. range 20-50°C
- Balancing valve
- Secondary loop 3/4" Eurocone
- Primary valves with clamp connection for CU-Pipe 15mm
- For control of UFH in small zones
- Max. primary temperature: 90°C
- Max. secondary temperature: 55°C
- Pumpgroup with thermostat 12-28°C
- Secondary max. temperature limiter 50°C
- Room sensor head with capillary sensor

GF Uponor Fluvia T pump group Push-12 CH-G

- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W

- Bracket for left- or right installation

- Air bleed screw
- Secondary circuit temp. range 20-50°C

- Balancing valve
- Secondary loop 3/4" eurocone

- Primary valves with clampconnection for CU-Pipe 15mm

- For control of UFH in small zones
- Max. primary temperature: 90°C

- Max. secondary temperature: 55°C
- With cartridge heater for UFH in summer mode
- Room temperature control by controller X-161
- Compatible to Uponor Smatrix Wave thermostats T-166, T-168 , T-169
- With safety sensor against overheating
- Secondary max. temperature limiter by 50°C

GF Uponor Fluvia T pump group Push-12 AC-G

- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W
- Bracket for left or right installation
- Air bleed screw
- Secondary circuit temp. range 20-50°C
- Balancing valve
- Secondary loop 3/4" Eurocone
- Primary valves with clampconnection for CU-Pipe 15mm
- For control of UFH in small zones
- Max. primary temperature: 90°C
- Max. secondary temperature: 55°C
- Pumpgroup with actuator 230 V and cable room sensor
- Secondary max. temperature limiter 50°C

GF Uponor Fluvia T pump group MPG-UK

- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W
- Bracket for left or right installation
- Air bleed screw
- Secondary circuit temp. range 20-50°C
- Balancing valve
- Secondary loop 3/4" Eurocone
- Primary valves with clamp connection for CU-Pipe 15mm
- For control of UFH in small zones
- Max. primary temperature: 90°C
- Max. secondary temperature: 55°C
- Maximal heat load: 15 kW
- kvs flow valve: 3,2 m3/h
- Water temperature and flow rates controlled by thermostatic 4 way valve