Catalogue
GF Uponor Vario PLUS supply valve inset scale 1-5, scale 1-5
- For flow regulation in supply bar in Vario Plus manifold - With shut-off function
GF Uponor Vario PLUS return valve inset
- For flow regulation in return, shut-off function
GF Uponor Vario PLUS thermometer
- Made of polycarbonate - For mounting at the connection set - Consists of two click thermometers
GF Uponor Vario flowmeter MF
GF Uponor Vario supply valve inset COMP
GF Uponor Fluvia T pump group Push-12 TH-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W - Bracket for left or right installation - Air bleed screw - Secondary circuit temp. range 20-50°C - Balancing valve - Secondary loop 3/4" Eurocone - Primary valves with clamp connection for CU-Pipe 15mm - For control of UFH in small zones - Max. primary temperature: 90°C - Max. secondary temperature: 55°C - Pumpgroup with thermostat 12-28°C - Secondary max. temperature limiter 50°C - Room sensor head with capillary sensor
GF Uponor Fluvia T pump group Push-12 CH-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- With cartridge heater for UFH in summer mode- Room temperature control by controller X-161- Compatible to Uponor Smatrix Wave thermostats T-166, T-168 , T-169- With safety sensor against overheating- Secondary max. temperature limiter by 50°C
GF Uponor Fluvia T pump group Push-12 AC-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W - Bracket for left or right installation - Air bleed screw - Secondary circuit temp. range 20-50°C - Balancing valve - Secondary loop 3/4" Eurocone - Primary valves with clampconnection for CU-Pipe 15mm - For control of UFH in small zones - Max. primary temperature: 90°C - Max. secondary temperature: 55°C - Pumpgroup with actuator 230 V and cable room sensor - Secondary max. temperature limiter 50°C
GF Uponor Fluvia T pump group MPG-UK
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W - Bracket for left or right installation - Air bleed screw - Secondary circuit temp. range 20-50°C - Balancing valve - Secondary loop 3/4" Eurocone - Primary valves with clamp connection for CU-Pipe 15mm - For control of UFH in small zones - Max. primary temperature: 90°C - Max. secondary temperature: 55°C - Maximal heat load: 15 kW - kvs flow valve: 3,2 m3/h - Water temperature and flow rates controlled by thermostatic 4 way valve
.jpg?sitename=Global&ext=.jpg&height=212)