Uponor Smatrix Base slave module M-140 Bus

- 6 channel slave module for Uponor Smatrix Base controller X-145 Bus 6X and Uponor Smatrix Base PRO controller X-147
- Bus 6X and Uponor Smatrix Base pro controller X-148 Modbus RTU
- Supports up to 6 room thermostats and 6 actuators
- Click-in installation
- Protection class: IP20
- Colour: grey

Uponor Smatrix Base slave module M-140 Bus

Item details

Uponor Smatrix Base slave module M-140 Bus 6x

Documents

Installation Report
2 KB1143292

IR Smatrix Base PRO UK 1143292 v1

Quick Guide
669 B1088246

Quick Guide Smatrix Base PRO R-147 KNX (1088246)

Installation and Operation Manual
1 KB1088247

Installation and Operation Manual Smatrix Base PRO R-147 KNX (1088247)

Approval Certificate
98 B1137326

UPONOR CER CONTROLS AND OTHERS PARTS UKCA UK (1137326)

EU declaration of conformity
1 KB1132746

Uponor DoC Smatrix 1071651 INT (1132746)

About

Specification

- Autobalancing optimizing energy use and comfort
- Up to 6 room thermostats and 8 actuators (24V) per
controller; 6 channel expansion module option
(with M-140)

Smatrix Base PRO controller X-147 with optional touch screen
I-147 and KNX option
- Up to 16 controller in one system
- Daisy chain wiring or star wiring (with M-141)
- Optional: display for controller information and settings
(with I-147)
- Optional: BMS integration via KNX interface
(with R-147 and I-147)

Comfort settings comprises (with I-147)
-Temperature setback programs for each channel
- Max/min temperature limitations and relative humidity
control
- Holiday settings and automatic summer/winter change
- Room bypass function
- Advance cooling settings and automatic summer/winter
change
- Trend visualization (set point vs. room temperature, etc.)
- Accessories configuration
- Room check function and system diagnostic

Smatrix Base PRO controller X-148 Modbus RTU
Read data points
- Temperature: outdoor / room / floor
- Humidity level
- Status of: actuator / pump / boiler / general purpose
input (GPI)
- Connection status of thermostat
- Dynamic heat curve offset in integrated heat pump
Read and write data points
- Room setpoint
- Min/max levels for: setpoint / floor temperature
- Settings: comfort/eco and autobalancing on/off
- Heating/cooling: state / offset
- Cooling not allowed for a room
- Integrated heat pump defrost state

Application

- Wired room temperature control for radiant heating and
cooling
- Set point range: +5°C - +35°C

Certification

- CE, EAC

Product drawings

1071686_REN
1071686
17 B
1071686_REN
1071686
17 B
1071686_PHO
1071686_PHO
599 B