Fill the BIM cart from the product catalogue

Uponor S-Press reducer PPSU

- Fast installation with easy bevel and without need for calibration
- Inspection windows on press sleeve
- Colour code

Uponor S-Press reducer PPSU

Item details

Uponor S-Press reducer PPSU 50-40
Uponor S-Press reducer PPSU 63-40
Uponor S-Press reducer PPSU 63-50
Uponor S-Press reducer PPSU 75-50
Uponor S-Press reducer PPSU 75-63

Documents

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
264 B1120771

UPONOR CER S-PRESS SYS MECH WRAS 2101908 GB EN (1120771)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

Approval Certificate
409 B1013450

UPONOR SAMPLE MLC PIPE WHITE 50X4,5 LENGTH 30CM

Environmental Product Declaration (EPD)
906 B1162874

Uponor EPD S-Press (1162874)

Brochure
277 B1141469

UPONOR DGNB S-PRESS PLUS PPSU 40-75 Fittings (1141469)

About

Specification

- Tin-plated brass or PPSU
- With fixed press sleeve
- Stop ring
- Colour code
- Test safety
- Male and female threads to BS EN 10226-1

Application

Tested/approved according to BS EN ISO 21003 Multilayer
piping systems for hot and cold water installations inside
buildings for application class 1,2,4,5/10bar

Domestic water services: The permanent operating
temperature from 20°C to 70°C at a maximum permanent
operating pressure of 10 bar. The short-term malfunction
temperature is 95°C for a period of 100 hours in the operating
life time.

Domestic cold water services : where the water temperature
does not exceed 20°C at a maximum permanent operating
pressure of 16bar.

Heating: The permanent operating temperature ranges up
to 80°C at a maximum permanent operating pressure of 10 bar.
The short-term malfunction temperature is 100°C for a period
of 100 hours in the operating life time.

Certification

UK Reg4 approval
- WRAS or
- KIWA
To meet the requirements of the Water Supply (Water Fittings) Regulations 1999

Product drawings

1032883_ZMD
1032883
133 B
1032884_ZMD
1032884
133 B
1032885_ZMD
1032885
133 B
1032886_ZMD
1032886
133 B
1046406_ZMD
1046406
133 B
1032883_LAB
1032883
80 B
1032884_LAB
1032884
77 B
1032885_LAB
1032885
86 B
1032886_LAB
1032886
76 B
1046406_LAB
1046406
82 B
1032883_REN
1032883
71 B
1032884_REN
1032884
75 B
1032885_REN
1032885
83 B
1032886_REN
1032886
80 B
1046406_REN
1046406
79 B
1046406_REN
1046406
74 B