Fill the BIM cart from the product catalogue

Uponor S-Press tee reducer PPSU

- Fast installation with easy bevel and without need for calibration
- Inspection windows on press sleeve
- Colour code

Uponor S-Press tee reducer PPSU

Item details

Uponor S-Press tee reducer PPSU 50-40-50
Uponor S-Press tee reducer PPSU 63-25-63
Uponor S-Press tee reducer PPSU 63-32-63
Uponor S-Press tee reducer PPSU 63-40-63
Uponor S-Press tee reducer PPSU 75-32-75
Uponor S-Press tee reducer PPSU 75-40-75
Uponor S-Press tee reducer PPSU 75-50-75

Documents

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
264 B1120771

UPONOR CER S-PRESS SYS MECH WRAS 2101908 GB EN (1120771)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

Approval Certificate
409 B1013450

UPONOR SAMPLE MLC PIPE WHITE 50X4,5 LENGTH 30CM

Environmental Product Declaration (EPD)
906 B1162874

Uponor EPD S-Press (1162874)

Brochure
277 B1141469

UPONOR DGNB S-PRESS PLUS PPSU 40-75 Fittings (1141469)

About

Specification

- Tin-plated brass or PPSU
- With fixed press sleeve
- Stop ring
- Colour code
- Test safety
- Male and female threads to BS EN 10226-1

Application

Tested/approved according to BS EN ISO 21003 Multilayer
piping systems for hot and cold water installations inside
buildings for application class 1,2,4,5/10bar

Domestic water services: The permanent operating
temperature from 20°C to 70°C at a maximum permanent
operating pressure of 10 bar. The short-term malfunction
temperature is 95°C for a period of 100 hours in the operating
life time.

Domestic cold water services : where the water temperature
does not exceed 20°C at a maximum permanent operating
pressure of 16bar.

Heating: The permanent operating temperature ranges up
to 80°C at a maximum permanent operating pressure of 10 bar.
The short-term malfunction temperature is 100°C for a period
of 100 hours in the operating life time.

Certification

UK Reg4 approval
- WRAS or
- KIWA
To meet the requirements of the Water Supply (Water Fittings) Regulations 1999

Product drawings

1032889_ZMD
1032889
171 B
1032890_ZMD
1032890
171 B
1032891_ZMD
1032891
171 B
1032892_ZMD
1032892
171 B
1032893_ZMD
1032893
171 B
1032894_ZMD
1032894
171 B
1046400_ZMD
1046400
171 B
1032889_LAB
1032889
71 B
1032890_LAB
1032890
74 B
1032891_LAB
1032891
74 B
1032892_LAB
1032892
77 B
1032893_LAB
1032893
76 B
1032894_LAB
1032894
78 B
1046400_LAB
1046400
90 B
1032889_REN
1032889
76 B
1032890_REN
1032890
78 B
1032891_REN
1032891
73 B
1032892_REN
1032892
88 B
1032893_REN
1032893
84 B
1032894_REN
1032894
87 B
1046400_REN
1046400
74 B