Fill the BIM cart from the product catalogue

Uponor S-Press tee reducer

- Made of tin-plated brass
- Fast installation with easy bevel and without calibration
- Inspection windows on press sleeve
- Colour code

Uponor S-Press tee reducer

Item details

Uponor S-Press tee reducer 40-20-40
Uponor S-Press tee reducer 40-25-32
Uponor S-Press tee reducer 40-25-40
Uponor S-Press tee reducer 40-32-32
Uponor S-Press tee reducer 40-32-40
Uponor S-Press tee reducer 50-25-40
Uponor S-Press tee reducer 50-25-50
Uponor S-Press tee reducer 50-32-50
Uponor S-Press tee reducer 50-40-50

Documents

Product Information
259 B1142159

PI MLC tap water heating UK 1142159

Installation Report
116 B1120119

Installation Report MLC leak test report TW water (1120119)

Installation Report
127 B1120120

Installation Report MLC flushing protocol TW water (1120120)

Approval Certificate
836 B1089107

UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)

Approval Certificate
409 B1013450

UPONOR SAMPLE MLC PIPE WHITE 50X4,5 LENGTH 30CM

Approval Certificate
409 B1013402

UPONOR SAMPLE MLC PIPE WHITE 32X3 LENGTH 30CM (1013402)

Environmental Product Declaration (EPD)
899 B1162876

Uponor EPD S-Press (1162876)

About

Specification

- Tin-plated brass or PPSU
- With fixed press sleeve
- Stop ring
- Colour code
- Test safety
- Male and female threads to BS EN 10226-1

Application

Tested/approved according to BS EN ISO 21003 Multilayer
piping systems for hot and cold water installations inside
buildings for application class 1,2,4,5/10bar

Domestic water services: The permanent operating
temperature from 20°C to 70°C at a maximum permanent
operating pressure of 10 bar. The short-term malfunction
temperature is 95°C for a period of 100 hours in the operating
life time.

Domestic cold water services : where the water temperature
does not exceed 20°C at a maximum permanent operating
pressure of 16bar.

Heating: The permanent operating temperature ranges up
to 80°C at a maximum permanent operating pressure of 10 bar.
The short-term malfunction temperature is 100°C for a period
of 100 hours in the operating life time.

Certification

UK Reg4 approval
- WRAS or
- KIWA
to meet the requirements of the Water Supply (Water Fittings) Regulations 1999

Product drawings

1046916_ZMD
1046916
177 B
1046918_ZMD
1046918
177 B
1046919_ZMD
1046919
177 B
1046920_ZMD
1046920
177 B
1046925_ZMD
1046925
177 B
1046916_REN
1046916
130 B
1046918_REN
1046918
130 B
1046919_REN
1046919
130 B
1046920_REN
1046920
130 B
1046925_REN
1046925
130 B
1046916_LAB
1046916
89 B
1046918_LAB
1046918
89 B
1046919_LAB
1046919
89 B
1046920_LAB
1046920
89 B
1046925_LAB
1046925
89 B