Item details
Documents
Technical manuals
Approval Certificate
Environmental Product Declaration (EPD)
Installation Report MLC leak test report TW water (1120119)
Installation Report MLC flushing protocol TW water (1120120)
UPONOR CER MLC SYS MECH Lloyds Register 17-20013-2 GB EN (1089107)
UPONOR SAMPLE MLC PIPE WHITE 32X3 LENGTH 30CM (1013402)
About
Specification
- Tin-plated brass or PPSU - With fixed press sleeve - Stop ring - Colour code - Test safety - Male and female threads to BS EN 10226-1
Application
Tested/approved according to BS EN ISO 21003 Multilayer piping systems for hot and cold water installations inside buildings for application class 1,2,4,5/10barDomestic water services: The permanent operating temperature from 20°C to 70°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 95°C for a period of 100 hours in the operating life time. Domestic cold water services : where the water temperature does not exceed 20°C at a maximum permanent operating pressure of 16bar.Heating: The permanent operating temperature ranges up to 80°C at a maximum permanent operating pressure of 10 bar. The short-term malfunction temperature is 100°C for a period of 100 hours in the operating life time.
Certification
UK Reg4 approval - WRAS or - KIWA to meet the requirements of the Water Supply (Water Fittings) Regulations 1999
Product drawings
Z-drawing
Rendered
Label drawings