Uponor Vario adapter Set
- Set of spare adapters (2 pcs.) for actuators cooperating with Vario manifolds- for Vario M, S manifold - 1 psc.- for Vario PLUS, MAGNA manifold - 1 psc.
- Set of spare adapters (2 pcs.) for actuators cooperating with Vario manifolds- for Vario M, S manifold - 1 psc.- for Vario PLUS, MAGNA manifold - 1 psc.
- C-Rail for fixation of manifold- with 5 dominos- with bolts 6mm, screws, nuts and washers
- Cabinet with door for on-wall installation- Galvanised steel, white powder coated (RAL 9016)- Without rear board- Lockable door with coin lock
- Complete cabinet with frame and door for in-wall installation- Depth: 110mm, extendable to 150mm- Hight adjustable: 730 - 930mm- Floor construction hight: max. 200mm- Material: galvanized steel- White powder coated frame and door (RAL 9016)- Lockable door
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4"" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Pumpgroup with thermostat 12-28°C- Secondary max. temperature limiter by 50°C- Room sensor head with capillary sensor
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4"" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- With cartridge heater for UFH in summer mode- Room temperature control by controller X-161- Compatible to Uponor Smatrix Wave thermostats T-166, T-168 , T-169- With safety sensor against overheating- Secondary max. temperature limiter by 50°C
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Pumpgroup with actuator 230 V and cable room sensor- Secondary max. temperature limiter by 50°C
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Pumpgroup with actuator 230 V, wireless thermostat and wireless receiver- Secondary max. temperature limiter by 60°C
- Pumpgroup pre-mounted - Water temperature and flow rates controlled by thermostat with capillary sensor,- Air bleed screw- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Balancing valve primary- Secondary connection G1 (MT)- For installation left or right of manifold- Maximal heat load: 10 kW- kvs flow valve: 1,2 m3/h
- Pre-mounted- Ball valve+balancing valve primary,- 3-way-mixing valve without motor drive- Air bleed screw- For installation left or right of manifold- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Connection G1 (MT) secondary
- Pre-mounted - Fluvia Move pump groups with supply temperature controller Uponor Smatrix Move- Fluvia T can be installed with brackets left or right on the installation- Max. primary temperature: 90°C- Max. secondary temperature: 55 - 60°C- For installation in central distribution room- Nominal heat output: 15 kW- Pump Wilo Para: Q: 0,1-2,5 m³/h, H: 6-2,4 m, EEI 0,17- Primary connection Rp1 (FT)- Secondary ball valves with thermometer, connection Rp1 (FT)- Uponor variable kvs-value and Uponor Smatrix move controler can be adapted