Pump Groups
Uponor Fluvia T pumpgroup Push-12 TH-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4"" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Pumpgroup with thermostat 12-28°C- Secondary max. temperature limiter by 50°C- Room sensor head with capillary sensor
Uponor Fluvia T pumpgroup Push-12 CH-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4"" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- With cartridge heater for UFH in summer mode- Room temperature control by controller X-161- Compatible to Uponor Smatrix Wave thermostats T-166, T-168 , T-169- With safety sensor against overheating- Secondary max. temperature limiter by 50°C
Uponor Fluvia T pumpgroup Push-12 AC-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Pumpgroup with actuator 230 V and cable room sensor- Secondary max. temperature limiter by 50°C
Uponor Fluvia T pumpgroup Push-12 WL-G
- Integrated pump: Q: 0,1 - 0,4 m³/h, H: 0,2 - 1,1 m, Phyd< 1W- Bracket for left- or right installation- Air bleed screw- Secondary circuit temp. range 20-50°C- Balancing valve- Secondary loop 3/4" eurocone- Primary valves with clampconnection for CU-Pipe 15mm- For control of UFH in small zones- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Pumpgroup with actuator 230 V, wireless thermostat and wireless receiver- Secondary max. temperature limiter by 60°C
Uponor Fluvia T pumpgroup Push-23-B-W
- Pumpgroup pre-mounted - Water temperature and flow rates controlled by thermostat with capillary sensor,- Air bleed screw- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Balancing valve primary- Secondary connection G1 (MT)- For installation left or right of manifold- Maximal heat load: 10 kW- kvs flow valve: 1,2 m3/h
Uponor Fluvia pumpgroup MPG-10-B-W
- Pre-mounted- Ball valve+balancing valve primary,- 3-way-mixing valve without motor drive- Air bleed screw- For installation left or right of manifold- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Connection G1 (MT) secondary
Uponor Fluvia pumpgroup CPG-15-D-W
- Pre-mounted - Fluvia Move pump groups with supply temperature controller Uponor Smatrix Move- Fluvia T can be installed with brackets left or right on the installation- Max. primary temperature: 90°C- Max. secondary temperature: 55 - 60°C- For installation in central distribution room- Nominal heat output: 15 kW- Pump Wilo Para: Q: 0,1-2,5 m³/h, H: 6-2,4 m, EEI 0,17- Primary connection Rp1 (FT)- Secondary ball valves with thermometer, connection Rp1 (FT)- Uponor variable kvs-value and Uponor Smatrix move controler can be adapted
Uponor Fluvia Move pumpgroup MPG-10-A-W
- Pumpgroup pre-mounted with supply temperature controller Uponor Smatrix Move- Outdoor temperature sensor (for installation on buildingsite)- Water temperature sensor for supply temperature- 3-way-mixing valve- Motor drive- Proportional pressure control- Upgrade to heating/cooling possible- For weather compensated supply water temperature control- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- Ball valve + balancing valve primary- Secondary connection G1 (MT)- For installation left or right of manifold
Uponor Fluvia Move pumpgroup CPG-15-C-W
- Pumpgroup pre-mounted with supply temperature controller Uponor Smatrix Move- Outdoor temperature sensor (for installation on buildingsite)- Water temperature sensor for supply temperature- 3-way-mixing valve- Motor drive- Proportional pressure control- Upgrade to heating/cooling possible- For weather compensated supply water temperature control- Max. primary temperature: 90°C- Max. secondary temperature: 55°C- For installation in central distribution room- Nominal heat output: 15 kW- Smatrix Move,variable kvs-value and motor 230V- Pump Wilo Para: Q: 0,1-2,5 m³/h, H: 6-2,4 m, EEI 0,17- Primary connection Rp1 (FT)- Secondary ball valves with thermometer, connection Rp1 (FT)
Uponor Fluvia Move pumpgroup EPG-6-A-W
- Pre-mounted - Fluvia Move pump groups with supply temperature controller Uponor Smatrix Move- Fluvia T can be installed with brackets left or right on the installation- Max. primary temperature: 90°C- Max. secondary temperature: 55 - 60°C- Necessary control accessories:- Uponor Smatrix Thermostat T-168 (1071689)- Uponor Smatrix Antenna (1071676)